Electromechanical engineering · Kigali, Rwanda · Since 2003 +250 782 212 428 WhatsApp [email protected]

Lightning protection · Schools & health facilities

Lightning protection for schools, hospitals and health centres in Rwanda.

Classrooms full of children, wards with patients on oxygen, vaccine fridges and new solar systems: buildings where a lightning strike costs the most. ELEMAC designs, installs and inspects their protection to NF C 17-102 and IEC 62305.

Standards

  • NF C 17-102 (ESE)
  • IEC 62305-2 (risk)
  • IEC 62305-3 (structures)
  • IEC 62305-4 (internal systems)
  • IEC 61643 (surge protection)

Brands we install

  • Aplicaciones Tecnológicas (AT3W)
  • TSTLP
  • Tosun Lux

Evidence

  • Independent lab test reports (LCOE, ICMET)
  • 14 lightning protection public contracts since 2019
  • Earth resistance recorded at every handover

Why schools and health facilities

Exposed buildings, many people, equipment that must keep running.

  • Exposed sites. Many schools and health centres stand on open hilltops, often the tallest structures around.
  • Many people outdoors. Pupils, patients and visitors move between buildings during the rainy seasons.
  • Critical equipment. Oxygen concentrators, vaccine fridges, laboratory and ICT equipment are destroyed by surges even when the building is not hit.
  • Solar systems. Off-grid schools and health posts rely on solar arrays and inverters that need their own surge protection.
Mast base with lightning strike counter and bilingual danger sign at a school
Strike counter and danger sign at a school installation.

What we deliver

From risk assessment to a handover file for every site.

Risk assessment

IEC 62305-2 risk calculation for each building to set the protection level, or a programme-wide assessment for a group of similar sites.

ESE or conventional system

ESE masts designed to NF C 17-102, or rods and meshed conductors to IEC 62305-3, chosen for the site layout and budget.

Earthing

Earth rods, copper tape, conductive compound and exothermic welds, with inspection pits for testing.

Surge protection

Surge protective devices on the main board, solar PV strings, inverters and data lines.

Signs, counters, training

Danger signs, optional strike counters, and a short briefing for the caretaker or maintenance staff.

Handover and inspection

Drawings, earth resistance readings and photos at handover; annual inspection with a written report.

Track record

Schools, hospitals and sites that host families.

Energy2024

Energy Development Corporation Ltd (EDCL)

Lightning protection for solar-electrified schools in off-grid areas

Location
Off-grid schools, Rwanda
Scope
Supply and installation of lightning protection for schools electrified with solar in off-grid areas.
Result
Schools and their new solar installations protected against lightning.
Related service
Health2025

University Teaching Hospital of Butare (CHUB)

Full lightning protection system for critical medical facilities

Location
Huye, Southern Province
Scope
Design, supply and installation of a complete lightning protection system for critical medical facilities.
Result
Critical hospital buildings protected against direct strikes and surges.
Related service
Health2020/21

Kibogora District Hospital

Lightning protection for a district hospital

Location
Kibogora, Nyamasheke District
Scope
Supply and installation of thunder and lightning protection at Kibogora District Hospital, after an air-conditioning installation contract in 2020.
Related service
Government2023

MINEMA, Ministry in charge of Emergency Management

Lightning protection at sites hosting families affected by the May 2023 disasters

Location
Disaster-risk locations, Rwanda
Scope
Supply and installation of lightning protection systems at sites accommodating families affected by the disasters of 2–3 May 2023.
Related service

See all 97 public contracts

Price guide

What affects the price of lightning protection.

Every quote follows a site survey, because no two sites are alike. These are the factors that move the price most.

Building size and height

Taller and larger buildings need a higher mast or more terminals, and more down conductors.

Protection level

Level I and II (hospitals, schools, fuel stores) need more conductors, closer spacing and more frequent inspection than level III or IV.

Ground conditions

Rocky or dry soil needs more earth electrodes and conductive compound to reach a low earth resistance.

Surge protection scope

Protecting only the main board costs less than adding protection for solar, data, CCTV and telecom lines.

Number of sites and distance

Programmes covering many similar sites share design and travel costs; remote single sites cost more per site.

Access

Steep roofs, tall structures and occupied buildings may need scaffolding, a crane or rope access.

Want a first estimate before calling? The free risk assessment tool gives the protection level and a bill of materials for your building.

Annual inspection

Is your system due for inspection?

IEC 62305-3 recommends a visual inspection every one to two years and a complete inspection every two to four years, depending on the protection level. Critical facilities such as hospitals should be checked every year, and any system after a known strike.

  • Air terminal, mast and down conductors
  • Continuity and earth resistance at every pit
  • Strike counter and surge protection devices
  • Written report with photos and recommended repairs

See a sample inspection report

Book an annual inspection

FAQs

Questions from schools and health facilities.

Can you protect a school that runs on solar power?

Yes. We protect the buildings with an ESE or conventional system and add surge protection on the solar array, the charge controller or inverter and the distribution board, as we did for solar-electrified schools in off-grid areas under the EDCL programme.

Can one contract cover many schools or health centres?

Yes. For ministries, districts and programmes we use a standard design per site type, plan installation across districts and give each site the same handover file: drawings, earth resistance readings and photos.

What does the annual inspection include?

A visual check of the air terminal, mast and down conductors, continuity checks, earth resistance measured at each inspection pit, a strike counter reading, a check of the surge protection devices, and a written report with photos and any repairs needed.

Do you inspect systems installed by other contractors?

Yes. We inspect and test existing systems, report defects and carry out the repairs needed to bring them back to standard.

Do you put up warning signs?

Yes. Masts are fitted with a danger sign and, where specified, a lightning strike counter, so caretakers know the system is there and when an inspection is due.

Request a lightning protection site survey

Takes about a minute. Only fields marked * are required.

Request type
How should we contact you?
Add email, organisation, budget and timeline (optional)