Electromechanical engineering · Kigali, Rwanda · Since 2003 +250 782 212 428 WhatsApp [email protected]

Lightning protection · Flagship

Lightning protection in Rwanda: design, supply, installation and testing.

Since 2003 ELEMAC has protected schools, hospitals, government facilities, national parks and industry from lightning, to NF C 17-102 and IEC 62305 standards.

Standards

  • NF C 17-102 (ESE)
  • IEC 62305-2 (risk)
  • IEC 62305-3 (structures)
  • IEC 62305-4 (internal systems)
  • IEC 61643 (surge protection)

Brands we install

  • Aplicaciones Tecnológicas (AT3W)
  • TSTLP
  • Tosun Lux

Evidence

  • Independent lab test reports (LCOE, ICMET)
  • 14 lightning protection public contracts since 2019
  • Earth resistance recorded at every handover

Why it matters

One strike can cost lives, buildings and equipment.

Lightning is destructive. It destroys electrical and electronic equipment, starts fires and causes electrocution and burns to people and livestock. The damage to buildings and equipment, and the downtime that follows, lead to serious economic losses.

Rwanda's hilly terrain and two rainy seasons make protection a priority for schools, health facilities, public offices, telecom sites and industrial plants, many of which stand on exposed hilltops.

Lightning protection for schools and health facilities

Lightning striking near buildings at night

Step 1 · Risk assessment

Start with the risk, not the product.

Every design begins with a lightning risk assessment that determines whether protection is needed and which protection level applies.

Site exposure

Location, altitude, surrounding structures and local lightning activity.

Building & use

Height, construction, roof type, occupancy and what the building contains.

Services

Incoming power, data and telecom lines that can carry surges inside.

Protection level

The resulting level (I to IV) sets terminal radius, conductors and inspection intervals.

Run the risk assessment for your building now

IEC 62305-2 risk calculation, required protection level, ESE terminal sizing to NF C 17-102, earthing, surge protection and a bill of materials, in two minutes.

Open the risk assessment tool

Step 2 · How an ESE system works

Capture the strike, carry it down, spread it safely into the ground.

Diagram of an early streamer emission lightning protection system on a building 1 2 3 4 5
  1. ESE air terminal. Mounted above the highest point, it emits an upward streamer early to capture the strike within a defined protection radius.
  2. Down conductors. Copper tape carries the current safely down the outside of the building.
  3. Test joint & strike counter. Allows inspection and records every strike.
  4. Earthing system. Rods, copper tape and conductive compound, joined by exothermic welding, disperse the energy into the ground.
  5. Surge protection. Protective devices on power, data and telecom lines protect the equipment inside.

Step 3 · Products

Tested components, in stock in Kigali.

We work with AT3W, Aplicaciones Tecnológicas (Spain), a specialist manufacturer of lightning protection, earthing and surge protection, and keep materials in stock so installations and repairs are not delayed by imports.

  • ESE air terminals (Pulsar, Nimbus, Duval Messien, TSTLP)
  • Conventional air rods and fittings
  • Tinned copper tape and conductors
  • Earth rods and inspection pits
  • Conductiver Plus conductive gel
  • Exothermic welding
  • Surge protection devices: power, signal, network (Aplicaciones Tecnológicas, TSTLP)
  • Solar PV surge protectors up to 1000 VDC (Tosun Lux)
  • Lightning strike counters (IP68)
  • DAT Controler Remote ESE terminals with remote verification (Aplicaciones Tecnológicas)
  • ATSTORM storm detectors and early-warning systems
  • Equipotential bonding bars, inspection pits and connection hardware
  • TSTLP ESE adapters for copper tape or cable
  • ATPLUG and ATSOCKET plug-in transient surge protection
  • Surge protection modules and DIN-rail fuse holders
  • Earth resistance testers
TSTLP ESE air terminal on a Kigali rooftop DAT Controler Remote ESE air terminal with remote verification
ATSTORM thunderstorm detection and early warning system Lightning strike counter on a down conductor

Monitoring & early warning

Know when a storm is approaching, and what has struck.

Protection is stronger when you can see what is happening. We supply and install monitoring that tells site managers when to act and keeps a record for maintenance:

  • ATSTORM storm detectors give early warning of approaching thunderstorms, with alerts on screen and on mobile, so outdoor work, events and sensitive processes can be stopped in time.
  • DAT Controler Remote ESE terminals report their status remotely, so you can check the rooftop terminal without climbing to it.
  • Lightning strike counters on the down conductor record every discharge and tell you when an inspection is due.
Discuss site alerts

Step 4 · Installation

Installed by teams experienced in vertical works.

Design & calculation

Protection radius, terminal height, number and route of down conductors, separation distances and earthing layout, documented on drawings.

Installation

Mast and terminal mounting, conductor routing, test joints, earth electrodes and exothermic welds, with surge protection in the distribution boards.

Multi-site delivery

Standard designs and planned schedules for programmes across many districts, with consistent quality and reporting for every site.

Price guide

What affects the price of lightning protection.

Every quote follows a site survey, because no two sites are alike. These are the factors that move the price most.

Building size and height

Taller and larger buildings need a higher mast or more terminals, and more down conductors.

Protection level

Level I and II (hospitals, schools, fuel stores) need more conductors, closer spacing and more frequent inspection than level III or IV.

Ground conditions

Rocky or dry soil needs more earth electrodes and conductive compound to reach a low earth resistance.

Surge protection scope

Protecting only the main board costs less than adding protection for solar, data, CCTV and telecom lines.

Number of sites and distance

Programmes covering many similar sites share design and travel costs; remote single sites cost more per site.

Access

Steep roofs, tall structures and occupied buildings may need scaffolding, a crane or rope access.

Want a first estimate before calling? The free risk assessment tool gives the protection level and a bill of materials for your building.

Step 5 · Testing & maintenance

A system is only as good as its last inspection.

At handover we measure earth resistance, check continuity and record the results. After that, regular inspection keeps the system effective. IEC 62305-3 recommends:

Protection levelVisual inspectionComplete inspectionCritical systems
I and IIEvery yearEvery 2 yearsEvery year
III and IVEvery 2 yearsEvery 4 yearsEvery year

Systems should also be checked after any known strike. Our preventive maintenance contracts cover inspection, testing, repairs and spare parts.

Book an annual inspection

Earth resistance tester reading 2.46 ohms at an inspection pit
Earth resistance measured on site by our team: 2.46 Ω at the inspection pit.

Annual inspection

Is your system due for inspection?

Book a yearly inspection for systems we installed or systems installed by others. We check every part, measure earth resistance and give you a written report with photos.

  • Air terminal, mast and down conductors
  • Continuity and earth resistance at every pit
  • Strike counter and surge protection devices
  • Written report with photos and recommended repairs

See a sample inspection report

Many sites at once? Ask about a maintenance plan.

Book an annual inspection

Standards

Designed and installed to recognised standards.

NF C 17-102

French standard for early streamer emission (ESE) lightning protection systems.

IEC 62305

International series for lightning protection: risk, structures and internal systems.

IEC 61643

Surge protective devices for low-voltage power and signal systems.

Lab-tested

Manufacturer test reports from independent laboratories such as LCOE and ICMET, on request.

On site

Our lightning protection work.

ESE masts for schools, earth resistance testing at every installation, and training for the people who look after the systems.

ESE lightning protection mast installed at a school in Rwanda
ESE mast protecting a school
ELEMAC lightning protection training session
Lightning protection training
Earth resistance tester in use on site
Earth resistance testing
Mast base with lightning strike counter and bilingual danger sign at a school
Strike counter and warning sign
ELEMAC technician installing earthing inspection pits
Installing earthing inspection pits

Track record

Recent lightning protection projects.

Government2025/26

Rwanda Broadcasting Agency (RBA)

Radio and TV electrical network, earthing and lightning protection

Location
RBA radio and TV sites
Scope
Electrical network, firefighting, earthing and lightning arrester infrastructure, tower maintenance and tower light replacement for radio and TV, after UPS supply (2021) and technical and electrical supply contracts since 2019.
Related service
Government2020 & 2026

Rwanda Correctional Service (RCS)

Lightning protection at correctional facilities

Location
Gisumbi and Musanze prisons, and other RCS sites
Scope
Supply and installation of lightning rod systems at Gisumbi and Musanze prisons (2019/20) and lightning conductors under the 2025/26 electricity power system contracts.
Related service
Health2025

University Teaching Hospital of Butare (CHUB)

Full lightning protection system for critical medical facilities

Location
Huye, Southern Province
Scope
Design, supply and installation of a complete lightning protection system for critical medical facilities.
Result
Critical hospital buildings protected against direct strikes and surges.
Related service
Industrial2025

Trinity Metals

Lightning protection at three mine sites

Location
Rutongo, Nyakabingo and Musha mines
Scope
Lightning protection for head offices, a server room, solar installations, a fuel station and hazardous storage areas at the Rutongo, Nyakabingo and Musha mine sites.
Related service
Energy2024

Energy Development Corporation Ltd (EDCL)

Lightning protection for solar-electrified schools in off-grid areas

Location
Off-grid schools, Rwanda
Scope
Supply and installation of lightning protection for schools electrified with solar in off-grid areas.
Result
Schools and their new solar installations protected against lightning.
Related service
GovernmentRecent

MINEMA, Ministry in charge of Emergency Management

Lightning protection contract, Lot 3 (Northern Province)

Location
Northern Province
Scope
Lightning protection installations under Lot 3 (North) of a national programme.
Related service
Government2023

MINEMA, Ministry in charge of Emergency Management

Lightning protection at sites hosting families affected by the May 2023 disasters

Location
Disaster-risk locations, Rwanda
Scope
Supply and installation of lightning protection systems at sites accommodating families affected by the disasters of 2–3 May 2023.
Related service
Government2020–2022

MINEMA, Rutsiro District programme

Lightning protection programme in Rutsiro District, in phases

Location
Rutsiro District, Western Province
Scope
Supply and installation of lightning protection systems across sites in Rutsiro District under three successive contracts, including a phase two.
Related service
Government2021/22

Rwanda Development Board (RDB)

Lightning arresters in GMNP national park

Location
GMNP national park sites
Scope
Supply, installation and commissioning of lightning arresters (protection) in GMNP.
Related service
Health2020/21

Kibogora District Hospital

Lightning protection for a district hospital

Location
Kibogora, Nyamasheke District
Scope
Supply and installation of thunder and lightning protection at Kibogora District Hospital, after an air-conditioning installation contract in 2020.
Related service
Government2020

Rwanda Development Board (RDB)

Lightning arresters at Volcanoes National Park offices

Location
Volcanoes National Park, Musanze
Scope
Supply, installation and commissioning of four lightning arresters at Volcanoes National Park offices.
Related service

All projects

FAQs

Lightning protection questions.

What is an ESE lightning protection system?

An early streamer emission (ESE) system uses an air terminal that emits an upward streamer earlier than a simple rod, giving a larger protection radius. It is designed to the French standard NF C 17-102 and connected to down conductors and an earthing system.

What standards do you design to?

ESE systems are designed to NF C 17-102. Conventional systems, earthing and surge protection follow the IEC 62305 series. Where required, we provide manufacturer test reports from independent laboratories such as LCOE and ICMET.

How often should a lightning protection system be inspected?

IEC 62305-3 recommends visual inspections every one to two years and complete inspections every two to four years depending on the protection level, with critical systems checked annually and any system checked after a known strike.

Does a lightning rod protect the equipment inside the building?

No. External protection protects the structure from direct strikes. Equipment needs surge protection devices on power, data and telecom lines, which we design together with the external system.

Can you protect many sites across different districts?

Yes. We deliver multi-site programmes for national institutions, with standard designs, planned installation and inspection schedules, and consistent reporting for every site.

Can you warn us before a thunderstorm arrives?

Yes. We supply and install ATSTORM storm detection systems that give early warning of approaching thunderstorms, with alerts on screen and mobile, so outdoor work and sensitive operations can be stopped in time.

Do you inspect systems installed by others?

Yes. We inspect and test existing systems, measure earth resistance, report defects and carry out the repairs needed to bring the system back to standard.

Read our lightning protection guides

Request a lightning protection site survey

Takes about a minute. Only fields marked * are required.

Request type
How should we contact you?
Add email, organisation, budget and timeline (optional)

Call WhatsApp